Clamp Meter PCE-PA 8000
Product Code: PCE-PA 8000
Clamp Meter PCE-PA 8000, HVAC Meter PCE-PA 8000, Three Phase Power Data Logger, Three- / 3-Phase-Power Meter, Clamp Meter, Power Analyzer, Current Clamp, Electrical Tester, Clamp on Tester: With the PCE-PA 8000 Clamp Meter you will be able to perform prolonged measurements of electrical properties. The measurement data is saved in xls format on the included SD card to be easily transferred to a computer or laptop for review. The Clamp Meter comes manufacturer calibrated and can be certified to ISO or UTIL standards as an option. - Display: 3.7 in / 94 mm LCD (320 x 240 pixels) with LED backlight - Electrical properties: AC V, AC A, active power, apparent power, power factor, phase angle, power frequency - Voltage ranges: 10 V ... 600 V AC, automatic range selection - Measures current up to 1200 A - Security / Standards: IEC1010CAT III 600V PCE-PA 8000 Clamp Meter real time measurement with registration in the SD card / integrated timer and calendar to record data / active, apparent, and reactive power The PCE-PA 8000 Clamp Meter is able to measure and record the power in both single-phase or three-phase circuits. With the PCE-PA 8000 Clamp Meter you will be able to perform prolonged measurements. Measurement values are saved in xls format on the included SD card of our Clamp Meter to be easily analyzed on the computer. Measurement rate can be set from 2 to 7200 seconds. The PCE-PA 8000 Clamp Meter can also measure power and determine both power factor and phase angle. The clamps of the PCE-PA 8000 Clamp Meter can be used for cables with a diameter of 50 mm / 2.0 in. The PCE-PA 8000 is the ideal tool to be used in power supply networks. Its 3.7 in / 94 mm display allows you to read all measured values for a quick analysis as well as providing a view of the current, voltage, and power. - Analysis of a network of 3 phases / 4 conductors, 3 phases / 3 conductors, 1 phase / 2 conductors, 1 phase / 3 conductors - Measures effective real value of current and voltage - Measures active, apparent, and reactive power - Power Factor (PF), phase angle (Φ) - Measures voltage up to 600 V - Measures current up to 1200 A - It meets the IEC 1010 and CAT III 600 V standards - Integrated timer and calendar to record data - Measured values are recorded in the included SD card - Data is stored in Excel format for further study - Data can be transferred to a PC through data cable - Large 3.7 in / 94 mm LCD display Technical Specifications Voltage (AC V) Measurement range Resolution Accuracy 10 V ... 600 V (phase to neutral) 0.1 V ±(0.5 % + 0.5 V) 10 V ... 600 V (phase to neutral) Current (AC A) Measurement range Resolution Accuracy 20 A 0.001 A (< 10 A) 0.01 A (≥ 10 A) ±(0.5 % + 0.1 V) 200 A 0.01 A (< 100 A) 0.1 A (≥ 100 A) ±(0.5 % + 0.5 A) 1200 A 0.1 A (< 1000 A) 1 A (≥ 1000 A) ±(0.5 A + 5 A) Active power Measurement range Resolution Accuracy 0 KW ... 9.999 KW 0.001 KW ±(1 % + 0.008 KW) 10 KW ... 99.99 KW 0.01 KW ±(1 % + 0.008 KW) 100 KW ... 999.9 KW 0.1 KW ±(1 % + 0.8 KW) 1 MW ... 9.999 MW 0.001 MW ±(1 % + 0.008 MW) Apparent power Measurement range Resolution Accuracy 0 KVA ... 9.999 KVA 0.001 KVA ±(1 % + 0.008 KVA) 10 KVA ... 99.99 KVA 0.01 KVA ±(1 % + 0.08 KVA) 100 KVA ... 999.9 KVA 0.1 KVA ±(1 % + 0.8 KVA) 1 MVA ... 9.999 MVA 0.001 MVA ±(1 % + 0.008 MVA) Reactive power Measurement range Resolution Accuracy 0 KVAR ... 9.999 KVAR 0.001 KVAR ±(1 % + 0.008 KVAR) 10 KVAR ... 99.99 KVAR 0.01 KVAR ±(1 % + 0.08 KVAR) 100 KVAR ... 999.9 KVAR 0.1 KVAR ±(1 % + 0.8 KVAR) 1 MVAR ... 9.999 MVAR 0.001 MVAR ±(1 % + 0.008 MVAR) Active energy Measurement range Resolution Accuracy 0 KWh ... 9.999 KWh 0.001 KWh ±(1 % + 0.008 KWh) 10 KWh ... 99.99 KWh 0.01 KWh ±(1 % + 0.08 KWh) 100 KWh ... 999.9 KWh 0.1 KWh ±(1 % + 0.8 KWh) 1 MWh... 9.999 MWh 0.001 MWh ±(1 % + 0.008 MWh) Apparent energy Measurement range Resolution Accuracy 0 KVAh ... 9.999 KVAh 0.001 KVAh ±(2 % + 0.008 KVAh) 10 KVAh ... 99.99 KVAh 0.01 KVAh ±(2 % + 0.08 KVAh) 100 KVAh ... 999.9 KVAh 0.1 KVAh ±(2 % + 0.8 KVAh) 1 MVAh... 9.999 MVAh 0.001 MVAh ±(2 % + 0.008 MVAh) Reactive energy Measurement range Resolution Accuracy 0 KVARh ... 9.999 KVARh 0.001 KVARh ±(2 % + 0.008 KVARh) 10 KVARh ... 99.99 KVARh 0.01 KVARh ±(2 % + 0.08 KVARh) 100 KVARh ... 999.9 KVARh 0.1 KVARh ±(2 % + 0.8 KVARh) 1 MVARh... 9.999 MVARh 0.001 MVARh ±(2 % + 0.008 MVARh) Power factor Measurement range Resolution Accuracy 0 ... 1 0.01 ±0.04 Phase angle Measurement range Resolution Accuracy -180º ... 180º 0.1º ±1º Frequency Measurement range Resolution Accuracy 45 Hz ... 65 Hz 0.1 Hz 0.1 Hz General specifications Display 3.7 in / 94.0 mm LCD (320 x 240 pixels) with LED backlight Electrical properties AC V, AC A, active power, apparent power, power factor, phase angle, mains frequency Voltage ranges 10 V ... 600 V AC, automatic range selection Security / Standards IEC1010CAT III 600V AC V input resistance 10 MΩ Operation frequency of current clamps 40 Hz ... 1 kHz Tested operation frequency of current clamps 45 Hz ...Visit the PCE Instruments UK Ltd website for more information on Clamp Meter PCE-PA 8000