Menu

Clamp Meter PCE-GPA 62

Product Code: PCE-GPA 62

Clamp Meter PCE-GPA 62: Three-Phase Clamp Meter with network analyzer / power and energy meter with data logger. he three-phase harmonic Analyzer (Graphic Power Quality Analyzer) is used for single-phase or three-phase measurements of active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50? of the harmonic waveform. This clamp meter is a perfect tool for all energetic measurements. It is delivered manufacturer calibrated and can be certified to ISO or standards. - Voltage measurement: 4.0 ... 600.0 V RMS value ± 0,5 %, ± 5   digits / 0,1 V - Voltage peaks (> 10V): 50 Hz - 60 Hz / ± 5 % ± 50 digits - Current measurements: 4.0 ... 1500.0 A real ± 1% V. ± 5 digits /   0,01 A - Current peaks (> 20A):  50 Hz - 60 Hz / ± 5 % ± 50 digits   Three-Phase Clamp Meter with network analyzer / power and energy meter (real time) with data logger, graphic display, interface for PC and software   The Three-Phase Clamp Meter (Graphic Power Quality Analyzer) PCE-GPA 62 is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50º of the harmonic waveform. The Three-Phase Clamp Meter PCE-GPA 62 comes with a built-in graphic display to show network analyzer values. Measured values can be both recorded and transferred to a PC for further analysis. The Three-Phase Clamp Meter PCE-GPA 62 is a professional handheld device to determine several parameters. Thanks to the backlight display, it is possible to get an accurate reading of measured values even with poor light conditions. Although the Three-Phase Clamp Meter PCE-GPA 62 comes calibrated from the manufacturer, an optional laboratory calibration and certificate, that meets ISO standards, can be ordered separately with the device or when an annual recalibration is required. - Real-time test, register and measurement of voltage and current (real effective) - Measures power factor and phase angle, frequency, energy, active, reactive and apparent power (single-   phase or three-phase in symmetrical networks). - Max. conductor diameter: 55 mm - Graphic display - Auto shut-off after 15 min. (this function may be disabled) - Optional ISO calibration Technical Specifications Voltage measurement 4,0 ... 600,0 V RMS value ± 0,5 % of the measured value ± 5 digits / 0,1 V Voltage peaks (> 10V) 50 Hz - 60 Hz / ± 5 % ± 50 digits Current measurements 4,0 ... 1500,0 A real ± 1% V. of the measured value ± 5 digits / 0,01 A Current peaks (> 20A) 50 Hz - 60 Hz / ± 5 % ± 50 digits Active power P 10 W ... 9999 kW in 5 measurement ranges ± 1 % of the value + 20 digits (>20 V y >20 A) ± 2 % of the value + 40 digits (>20 V y >20 A) 0,1 W ... 1 kW according to the measurement range Apparent power S 10 VA ... 9999 kVA in 5 measurement ranges ± 1 % of the value + 20 digits (>20 V y >20 A) ± 2 % of the value + 40 digits (>20 V y >20 A) 0,1 VA ... 1 kVA according to the measurement range Reactive power Q 10 VAr ... 9999 kVAr in 5 measurements ranges ± 1 % of the value + 20 digits (>20 V y >20 A) ± 2 % of the value + 40 digits (>20 V y >20 A) 0,1 VAr ... 1 kVAr according to the measurement range PF power factor 0,000 ... 1,000 ± 0,04 (>20 V >20 A) / 0,001 ± 0,1 (>20 V >20 A) / 0,001 Phase angle -180 ... +180 / ±1 / 0,1 0 ... +360 / ±1 / 0,1 Frequency measurement (U > 50 V) 46 ... 65 Hz ±0,3 Hz / 0,1 Hz Active energy 0 ... 999.999 kWh ± 1 % of the value + 20 digits Apparent energy 0 ... 999.999 kVAh ± 1 % of the value + 20 digits Reactive energy 0 ... 999.999 kVarh ± 1 % of the value + 20 digits Harmonics in the voltage (relative) 50 - 60 Hz > 80 V AC 1 - 20 th / ± 2 % / 0,1 % 21 - 50 th / ± 4 % of the value ± 2 % / 0,1 % Harmonics in the voltage (absolute) 50 - 60 Hz > 80 V AC 1 - 20 th / ± 2 % / 0,1 % 21 - 50 th / ± 4 % of the value ± 0,5 % / 0,1 % Harmonics in the current (relative) 50 - 60 Hz > 80 V AC 1 - 20 th / ± 2 % / 0,1 % 21 - 50 th / ± 4 % of the valuew ± 2 % / 0,1 % Harmonics in the current (absolute) 50 - 60 Hz > 80 V AC 1 - 20 th / ± 2 % of the value ± 0,4 A / 0,1 A 21 - 50 th / ± 4 % of the value ± 0,4 A / 0,1 A Total harmonic distortion (THD-F) 50 - 60 Hz > 80 V y > 20 A 0,0 - 20 % / 2 % / 0,1 % 20,1 - 100 % / ± 6 % of the value ± 1 % / 0,1 % 100,1 - 999,9 % / ± 10 % of the value ± 1 % / 0,1 % Max. clamp opening 55 mm Range selection auto Overload indication "OL = Overload Memory 50.000 readings Interface USB Software and data cable included in the delivery. They can be used with Win 2000, XP, y ME Display graphic LCD display, 128 x 64 with backlight Power supply 2x 1.5 V AA batteries Energy consumption aprox. 10 mA Dimensions 271 x 112 x 46 mm / 10.6 x 4.4 x 1.8 in Weight 650 g with batteries Operating conditions 85 % max. R.H. / -10 ... + 50 °C / 14 ... 122 °F Protection / Standards CAT III 600 V / EN 61010-2-032 Delivery contents : 1 x Three-Phase Clamp Meter PCE-GPA 62 2 x Isolated measuri

Visit the PCE Instruments UK Ltd website for more information on Clamp Meter PCE-GPA 62

ENQUIRY FORM

More Products

  • Clamp on Tester PCE-GPA 50

  • Clamp on Tester PCE-CM 3-ICA incl. ISO Calibration Certificate

  • Clamp-on Tester PCE-PCM 3

  • Clamp on Tester PCE-LCT 1-ICA incl. ISO Calibration Certificate