Clamp Meter PCE-830-3
Product Code: PCE-830-3
Clamp Meter PCE-830-3, Three-Phase Power Data Logger Meter, Data Logger, Clamp Meter, HVAC Meter, Power Analyzer, Power Meter, Current Clamp, Clamp on Tester, 3-Phase Power Meter: The PCE-830-3 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally. - PCE-830 + PCE-3007 flexible amp clamp (3000 A) - Electrical conductor pick-up: 170 mm / 6.69 in diameter - Length of electrical conductor: 610 mm / 24.0 in - Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in - Sampling rate: 2 sec. - Memory size: 512 kB (max. 52,000 values - single phase) PCE-830-3 Clamp Meter with 3 phases / measures power and analyses harmonics / includes memory, interface, and software The PCE-830 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The backlit LCD, with high resolution, can show up to 35 parameters simultaneously. Up to 3 clips can be attached at the same time to the Clamp Meter. In data logger mode, it can save up to 17,470 readings (3 phases / 4 conductors), in a simpler set up (1 phase / 2 conductors) it can save up to 52,400 readings, split into 85 groups. All this makes the PCE-830 Clamp Meter the ideal instrument for taking measurements over long durations. Measurement values obtained can be sent to a computer and be processed with the included analysis software. The device comes with everything needed to be measuring and analysing from the moment it arrives. Although the Clamp Meter comes calibrated from the manufacturer, an optional laboratory calibration and certificate, that meets ISO standards, can be ordered separately with the device or when a recalibration is required. - Analysis of a network of 3 phases / 4 conductors, 3 phases / 3 conductors, 1 phase / 2 conductors, 1 phase / 3 conductors - Measures effective real value (V 123 and I 123) - Measures active power (W, KW, MW, GW) - Measures apparent and reactive power (KVA, KVAR) - Power Factor (PF), phase angle (Φ) - Measures energy and work (Wh, KWh, KVARh, PFh) - Measures current from 0.1 mA to 3000 A, allowing for the reserve power of a factory to be determined - Large LCD that shows up to 35 parameters simultaneously (3P4W [=3 phases/4 conductors]) - CT conditions (1 to 600) and PT (1 to 3000) are programmable - Indicates current wave forms and voltage overlap. - 512 KB of memory with programmable intervals to save data every 2 to 3000 seconds, 17,470 readings using the system of 3 phases / 4 conductors - Indicates wave forms, efficiency parameters, and harmonic distortion - Backlit LCD with dot matrix - Average power (AD in W, KW, MW) - Maximum power (MD in W, KW, MW) with the programmable period - Analysis of harmonic distortion up to a curvature of 99 - Indication of up to 50º form of harmonic wave - Indication of the wave form with maximum value (1024 readings / period) - Analysis of absolute distortion (%THD-F) - Diagram of graphic equilibrium with parameters of a 3 phase system - Detects up to 28 transistors (time and cycles) with a programmable threshold (%) - Relation of 3 phases of voltage or asymmetrical current (VUR) - Factor of 3 phases of voltage and asymmetrical current (d0%, d2%) - USB port (optically insulated) - Integrated timer and calendar to record data - Maximum diameter of the electrical conductor for the amp clamp: the PCE-6801 ~30 mm / 1.2 in, PCE-6802 ~55 mm / 2.2 in, PCE-3007 ~170 mm / 6.7 in Technical Specifications Measurement values Measurement ranges / resolution / accuracy PCE-830 + PCE-3007 Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1) 10.0 W to 999.9 W / 0.1 W / ±1% of measurement range 1.000 kW to 9.999 kW / 0.001 kW / ±1% of measurement range 10.00 kW to 99.99 kW / 0.01 kW / ±1% of measurement range 100.0 kW to 999.9 kW / 0.1 kW / ±1% of measurement range 1000 kW to 9999 kW / 1 kW / ±1% of measurement range PCE-830 + PCE-3007 Current AC (50 Hz or 60 Hz, auto range select, TRMS) 0 to 300 A / 0.1 A / ±1.0% of measurement range 300.0 A to 999.9 A / 0.1 A / ±1.0% of measurement range 1000 A to 3000 A / 1 A / ±1.0% of measurement range Voltage AC (50 Hz or 60 Hz, TRMS) 20.0 V to 500.0 V / 0.1 V / ±0.5% ±5 digits (measure between phaseVisit the PCE Instruments UK Ltd website for more information on Clamp Meter PCE-830-3